Practical Physics |
From inside the book
Results 1-5 of 100
Page 15
... hence if one of the units of measurement is changed , the numerical measure of the same actual quan- tity will be changed in the inverse ratio , and the value of k will be thereby changed . in We may always determine the numerical value ...
... hence if one of the units of measurement is changed , the numerical measure of the same actual quan- tity will be changed in the inverse ratio , and the value of k will be thereby changed . in We may always determine the numerical value ...
Page 21
... hence we cannot reduce the variation equations to ordinary equalities . This is the case with the formula for the gaseous laws already mentioned ( p . 15 ) . A complete system of units has thus been formed on the C.G.S. absolute system ...
... hence we cannot reduce the variation equations to ordinary equalities . This is the case with the formula for the gaseous laws already mentioned ( p . 15 ) . A complete system of units has thus been formed on the C.G.S. absolute system ...
Page 27
... Hence s = vt , [ L ] [ T ] -1 . ~ = X = um ( 2 ) To find the Dimensional Equation for Force . Physical law f = ma . Hence but [ F ] = [ M ] [ a ] ; [ a ] = [ L ] [ T ] -2 .. [ F ] = [ M ] [ L ] [ T ] -2 . ( 3 ) To find the Dimensional ...
... Hence s = vt , [ L ] [ T ] -1 . ~ = X = um ( 2 ) To find the Dimensional Equation for Force . Physical law f = ma . Hence but [ F ] = [ M ] [ a ] ; [ a ] = [ L ] [ T ] -2 .. [ F ] = [ M ] [ L ] [ T ] -2 . ( 3 ) To find the Dimensional ...
Page 29
... Hence [ w ] = 454 × ( 305 ) 2 . 15 foot - pounds = 15 × 32 * 2 × 454 × ( 305 ) 2 ergs . = 2'04 × 10 % ergs . Sometimes neither of the units belongs strictly to an absolute system , although a change of the fundamental units alters the ...
... Hence [ w ] = 454 × ( 305 ) 2 . 15 foot - pounds = 15 × 32 * 2 × 454 × ( 305 ) 2 ergs . = 2'04 × 10 % ergs . Sometimes neither of the units belongs strictly to an absolute system , although a change of the fundamental units alters the ...
Page 37
... hence , in the mean obtained , all the figures after the fourth , at any rate , have no meaning . They are introduced simply by the arithmetical manipulation , and it is , therefore , better to discard them . It is , indeed , not only ...
... hence , in the mean obtained , all the figures after the fourth , at any rate , have no meaning . They are introduced simply by the arithmetical manipulation , and it is , therefore , better to discard them . It is , indeed , not only ...
Contents
49 | |
59 | |
66 | |
77 | |
85 | |
92 | |
99 | |
123 | |
132 | |
139 | |
152 | |
166 | |
174 | |
182 | |
188 | |
195 | |
202 | |
209 | |
226 | |
234 | |
244 | |
251 | |
265 | |
271 | |
279 | |
352 | |
367 | |
375 | |
383 | |
395 | |
404 | |
405 | |
412 | |
418 | |
425 | |
433 | |
441 | |
456 | |
484 | |
492 | |
526 | |
541 | |
548 | |
557 | |
567 | |
595 | |
604 | |
616 | |
629 | |
633 | |
Other editions - View all
Common terms and phrases
accuracy adjusted apparatus axis axis of rotation beam body bulb calorimeter centimetres centre circle coil coincide colour convex lens cross-wire cubic centimetres curve deflexion density determine disc distance division drying tubes electricity electromotive force Enter results equal equation experiment Experiment.-Determine eye-piece fixed focal length force formula galvanometer given glass glycerine grammes heat Hence horizontal hydrometer hypsometer inertia instrument lens light liquid magnet mass means measure mercury method micrometer microscope millimetre mirror moment of inertia moving object-glass observations obtained oscillation parallel passes pendulum piece placed plane pointer pole position pressure prism quantity radius ratio rays reading refraction refractive index resistance right angles rotation scale pans screw shew shewn slide slider slit specific gravity string suppose surface telescope temperature thermometer tube turn vapour velocity vernier vertical vessel vibration volume weight wire zero
Popular passages
Page 575 - It is nearly filled with the solution, and connected to the rest of the circuit by being placed on a clean copper support to which a binding screw is attached.
Page 575 - In determining by this method the constant of an instrument the current should be kept as nearly constant as possible, and the readings of the instrument observed at frequent intervals of time. These observations give a curve from which the reading corresponding to the mean current (time-average of the current) can be found. The current, as calculated by the voltameter, corresponds to this reading.
Page 575 - The anode is then to be immersed in the solution so as to be well covered by it and supported in that position ; the connections to the rest of the circuit are then to be made.
Page 14 - The rate of change of momentum is proportional to the impressed force, and takes place in the direction of the straight line in which the force acts.
Page 568 - Contact is made with the mercury by means of a platinum wire about No. 22 gauge. This is protected from contact with the other materials of the cell by being sealed into a glass tube. The ends of the wire project from the ends of the tube ; one end forms the terminal, the other end and a portion of the glass tube dip into the mercury.
Page 569 - Then insert the cork and zinc rod, passing the glass tube through the hole prepared for it. Push the cork gently down until its lower surface is nearly in contact with the liquid. The air will thus be nearly all expelled, and the cell should be left in this condition for at least 24 hours before sealing, which should be done as follows : — Melt some marine glue until it is fluid enough to pour by its own weight, and pour it into the test tube above the cork, using sufficient to cover completely...
Page 182 - If three forces acting at a point are in equilibrium they can be represented in magnitude and direction by the three sides of a triangle taken in order.
Page 568 - Mix the washed mercurous sulphate with the zinc sulphate solution, adding sufficient crystals of zinc sulphate from the stock bottle to ensure saturation, and a small quantity of pure mercury. Shake these up well together to form a paste of the consistence of cream. Heat the paste, but not above a temperature of 30° C.
Page 574 - The anode should be a plate of pure silver some 30 square centimetres in area and 2 or 3 millimetres in thickness. This is supported horizontally in the liquid near the top of the solution by a platinum wire passed through holes in the plate at opposite corners. To prevent the disintegrated silver which is formed on the anode from falling on to the kathode, the anode should be wrapped round with pure filter paper, secured at the back with sealing-wax.