Transactions of the American Institute of Electrical Engineers, Volumes 18-29American Institute of Electrical Engineers., 1913 - Electric engineering "Index of current electrical literature" Dec. 1887-1890 appended to v. 5-7. |
From inside the book
Results 1-5 of 85
Page 7
... phase and three - phase transmission lines , transformers and induction motors . Tables of react- ance , capacity , resistance and drop factors for use in such calculations . Discussion , pp . 1424-1427 , by Messrs . Comfort A. Adams ...
... phase and three - phase transmission lines , transformers and induction motors . Tables of react- ance , capacity , resistance and drop factors for use in such calculations . Discussion , pp . 1424-1427 , by Messrs . Comfort A. Adams ...
Page 12
... three - meter and polyphase meter methods for measuring energy in three - phase circuits . Discussion , incorporated with paper by W. J. Mowbray on " Main- tenance of Meters . " F. P. Cox NOTES ON THE USE OF INSTRUMENTS ON SWITCHBOARDS ...
... three - meter and polyphase meter methods for measuring energy in three - phase circuits . Discussion , incorporated with paper by W. J. Mowbray on " Main- tenance of Meters . " F. P. Cox NOTES ON THE USE OF INSTRUMENTS ON SWITCHBOARDS ...
Page 14
American Institute of Electrical Engineers. THREE - PHASE POWER FACTOR Austin Burt Vol . xxvii - 1908 , pp . 801-814 Derivation of formula for the mean power - factor of a three - phase system , together with a method of determining ...
American Institute of Electrical Engineers. THREE - PHASE POWER FACTOR Austin Burt Vol . xxvii - 1908 , pp . 801-814 Derivation of formula for the mean power - factor of a three - phase system , together with a method of determining ...
Page 35
... THREE - PHASE AND ONE - PHASE TRANSFORMERS H. W. Tobey Brief general remarks . Vol . xxvi - 1907 , pp . 813-815 Discussion , incorporated with paper by John S. Peck on " Relative Advantages of One - Phase and Three - Phase Transformers ...
... THREE - PHASE AND ONE - PHASE TRANSFORMERS H. W. Tobey Brief general remarks . Vol . xxvi - 1907 , pp . 813-815 Discussion , incorporated with paper by John S. Peck on " Relative Advantages of One - Phase and Three - Phase Transformers ...
Other editions - View all
Common terms and phrases
A. E. Kennelly A. H. Armstrong alternating-current alternators apparatus B. A. Behrend C. F. Scott C. O. Mailloux C. P. Steinmetz cables Carl Hering central station characteristics Charles F Chas circuits Clayton H commutation construction curves dielectric strength direct-current Discussion including distribution system effect ELECTRIC RAILWAY Elihu Thomson energy F. A. C. Perrine factors Frederick Bedell Gano Gano Dunn H. G. Stott H. W. Buck H. W. Fisher high-tension incorporated with paper induction motors insulation James Lyman L. B. Stillwell lighting lightning arresters Louis Bell Mershon Messrs method motor-generators N. J. Neall P. H. Thomas P. M. Lincoln parallel operation Percy H performance Philip Torchio power-factor railway motors Ralph Ralph D regulation relative merits remarks repulsion motor single-phase special reference SPEED CONTROL synchronous converters three-phase tion transformers transmission line various voltage W. E. Goldsborough W. L. Waters W. N. Smith W. S. Franklin William McClellan wire