Guide to the Practical Elements of Electrical Testing |
From inside the book
Results 1-5 of 36
Page
By P. C. Allsop. With 224 illusuations. Fourth edition, revised 8 0 Localisation of
Faults in Electric Light Mains. By F. C. Baphael 5 n 'Electric Lighting and Power
Distribution. By W. Perrsn Maycock, U.I.E.E. Fourth edition. Crown 8vo. In two
vols.
By P. C. Allsop. With 224 illusuations. Fourth edition, revised 8 0 Localisation of
Faults in Electric Light Mains. By F. C. Baphael 5 n 'Electric Lighting and Power
Distribution. By W. Perrsn Maycock, U.I.E.E. Fourth edition. Crown 8vo. In two
vols.
Page
... of Electromotive Force ... 107 116 9. The Determination of Current Strength 116
122 10. The Measurement of Electrostatic Capacity ... 122 >i 131 Combination
Testing Sets 131 ii 144 Localisation of Faults 144 ii 171 Joint Testing 171 u 174.
... of Electromotive Force ... 107 116 9. The Determination of Current Strength 116
122 10. The Measurement of Electrostatic Capacity ... 122 >i 131 Combination
Testing Sets 131 ii 144 Localisation of Faults 144 ii 171 Joint Testing 171 u 174.
Page 36
The shanks of the plugs are grooved at a point just below the upper surface of the
blocks when they are in position ; this grooving effectually prevents " shouldering,
" a fault to which the old form, of plugs were especially liable when they ...
The shanks of the plugs are grooved at a point just below the upper surface of the
blocks when they are in position ; this grooving effectually prevents " shouldering,
" a fault to which the old form, of plugs were especially liable when they ...
Page 67
... no deflection be obtained, there is a solution of continuity, and the fault must be
localised. To localise a disconnection the best plan is to divide the circuit up into
suitable sections ; thus, if it be an ordinary branch of electric light house wiring, ...
... no deflection be obtained, there is a solution of continuity, and the fault must be
localised. To localise a disconnection the best plan is to divide the circuit up into
suitable sections ; thus, if it be an ordinary branch of electric light house wiring, ...
Page 68
The National Telephone Company adopt the above simple system of circuit
testing universally for daily line teste and fault localisation, each exchange being
provided with ai detector outfit and special switching arrangements, by means of
...
The National Telephone Company adopt the above simple system of circuit
testing universally for daily line teste and fault localisation, each exchange being
provided with ai detector outfit and special switching arrangements, by means of
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Common terms and phrases
adjustable apparatus applied arms arranged balance base battery bridge Bros cable capacity cell charging circuit closed coil comparatively complete conducting conductor connected consequent consists constant constructed containing copper deflection depressed described determined difference direction discharge earth ebonite effect electrical employed equal extremity fault figure follows force galvanometer give glass illustrated indicated insulation known latter lead length lever magnetic manner means measurement mercury method mounted moving necessary needle noted obtained ohms ordinary passing period placed plugs pole position possible practical principle reading represented resistance respectively scale short shown shunt side similar simple slide solution spring standard standard cell suitable surface suspended switch taken taking temperature terminals tion tube turn unit usually vanometer varies voltage Wheatstone whilst wire zinc
Popular passages
Page 40 - It is convenient to arrange the mounting so that the cell may be immersed in a water bath up to the level of, say, the upper surface of the cork. Its temperature can then be determined more accurately than is possible when the cell is in air. " In using the cell, sudden variations of temperature should, as far as possible, be avoided.
Page 50 - As a unit of resistance, the international ohm, which is based upon the ohm equal to 10" units of resistance of the CGS system of electromagnetic units, and is represented by the resistance offered to an unvarying electric current by a column of mercury at the temperature of melting ice, 14.4521 grams in mass, of a constant cross-sectional area and of the length of 106.3 centimetres.
Page 40 - Then insert the cork and zinc rod, passing the glass tube through the hole prepared for it. Push the cork gently down until its lower surface is nearly in contact with the liquid. The air will thus be nearly all expelled, and the cell should be left in this condition for at least twenty-four hours before sealing, which should be done as follows.
Page 40 - Contact is made with the mercury by means of a platinum wire about No. 22 gauge. This is protected from contact with the other materials of the cell by being sealed into a glass tube. The ends of the wire project from the ends of the tube ; one end forms the terminal, the other end and a portion of the glass tube dip into the mercury.
Page 38 - ... carefully removing any loose pieces of the zinc. Just before making up the cell, dip the zinc into dilute sulphuric acid, wash with distilled water, and dry with a clean cloth or filter paper. 3. The Mercurous Sulphate.
Page 38 - CELL. Definition of the Cell. The cell consists of zinc or an amalgam of zinc with mercury and of mercury in a neutral saturated solution of zinc sulphate and mercurous sulphate in water, prepared with mercurous sulphate in excess. Preparation of the Materials. 1. The Mercury. — To secure purity it should be first treated with acid in the usual manner, and subsequently distilled in vacuo. 2. The Zinc. — Take a portion of a rod of pure redistilled zinc, solder to one end a piece...
Page 39 - Mix the washed mercurous sulphate with the zinc sulphate solution, adding sufficient crystals of zinc sulphate from the stock bottle to ensure saturation, and a small quantity of pure mercury. Shake these up well together to form a paste of the consistence of cream. Heat the paste, but not above a temperature of 30° C.
Page 40 - ... rod can pass tightly ; at the other side bore another hole for the glass tube which covers the platinum wire ; at the edge of the cork cut a nick through which the air can pass when the cork is pushed into the tube. Wash the cork thoroughly with warm water, and leave it to soak in water for some hours before use. Pass the zinc rod about 1 centimetre through the cork.
Page 39 - ... any free acid. The crystals should be dissolved with the aid of gentle heat, but the temperature to which the solution is raised should not exceed 30° C.
Page 20 - An example which deserves to be taken as a model by other authors. The subject Is treated In a manner which any intelligent man who is fit to be entrusted with charge of an engine should be able to understand.