Guide to the Practical Elements of Electrical Testing |
From inside the book
Results 1-5 of 30
Page 3
... N S is a pointer or index, not shown in the figure, which indicates1 the
movements of N S consequent upon the passage of a current, upon an engraved
dial plate mounted behind a protecting glass front, in one of the sides of the case.
... N S is a pointer or index, not shown in the figure, which indicates1 the
movements of N S consequent upon the passage of a current, upon an engraved
dial plate mounted behind a protecting glass front, in one of the sides of the case.
Page 8
Lamp Stand, with Transparent Galvanometer Scale, by Nalder Bros. is closely
surrounded by a small similarly-shaped chamber, closed, or nearly closed, on all
sides, the interior surfaces Fig. 5. of which only just clear the edges of the vane. 0.
Lamp Stand, with Transparent Galvanometer Scale, by Nalder Bros. is closely
surrounded by a small similarly-shaped chamber, closed, or nearly closed, on all
sides, the interior surfaces Fig. 5. of which only just clear the edges of the vane. 0.
Page 24
Passing through the centre of the circle enclosed by these strips was a vertical
suspension wire, carrying on one side of it, and at right angles to itself, a light
needle C. It is obvious that if this needle be charged with electricity of a certain
sign, ...
Passing through the centre of the circle enclosed by these strips was a vertical
suspension wire, carrying on one side of it, and at right angles to itself, a light
needle C. It is obvious that if this needle be charged with electricity of a certain
sign, ...
Page 25
The mirror and suspension adjustments are enolosed by ai protecting cover,
known as the " lantern," in the side of which an opening is left, closed by a glass
window, to permit of the mirror being used as in an ordinary reflecting
galvanometer ...
The mirror and suspension adjustments are enolosed by ai protecting cover,
known as the " lantern," in the side of which an opening is left, closed by a glass
window, to permit of the mirror being used as in an ordinary reflecting
galvanometer ...
Page 32
13, which is a side view of the ebonite lid, and some of the coils as they appear
when removed from the case. The object of the chamfering on the underside Fig.
13. of the blocks is to allow clearance for the removal of dust and dirt, which will ...
13, which is a side view of the ebonite lid, and some of the coils as they appear
when removed from the case. The object of the chamfering on the underside Fig.
13. of the blocks is to allow clearance for the removal of dust and dirt, which will ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Common terms and phrases
adjustable apparatus applied arranged balance base battery bridge cable capacity cell charging circuit closed coil comparatively complete conducting conductor connected consequent consists constant constructed containing copper deflection depressed described determined difference direction discharge earth ebonite effect electrical employed equal extremity fault figure follows force galvanometer give glass illustrated indicated insulation known latter lead length lever magnetic manner means measurement mercury method mounted moving necessary needle noted obtained ohms opposite ordinary passing period placed plug pole position possible practical principle reading remaining represented resistance respectively scale short shown shunt side similar simple slide spring standard standard cell suitable surface suspended switch taken taking temperature terminals tion tube turn unit usually vanometer varies voltage Wheatstone whilst wire zinc
Popular passages
Page 40 - It is convenient to arrange the mounting so that the cell may be immersed in a water bath up to the level of, say, the upper surface of the cork. Its temperature can then be determined more accurately than is possible when the cell is in air. " In using the cell, sudden variations of temperature should, as far as possible, be avoided.
Page 50 - As a unit of resistance, the international ohm, which is based upon the ohm equal to 10" units of resistance of the CGS system of electromagnetic units, and is represented by the resistance offered to an unvarying electric current by a column of mercury at the temperature of melting ice, 14.4521 grams in mass, of a constant cross-sectional area and of the length of 106.3 centimetres.
Page 40 - Then insert the cork and zinc rod, passing the glass tube through the hole prepared for it. Push the cork gently down until its lower surface is nearly in contact with the liquid. The air will thus be nearly all expelled, and the cell should be left in this condition for at least twenty-four hours before sealing, which should be done as follows.
Page 40 - Contact is made with the mercury by means of a platinum wire about No. 22 gauge. This is protected from contact with the other materials of the cell by being sealed into a glass tube. The ends of the wire project from the ends of the tube ; one end forms the terminal, the other end and a portion of the glass tube dip into the mercury.
Page 38 - ... carefully removing any loose pieces of the zinc. Just before making up the cell, dip the zinc into dilute sulphuric acid, wash with distilled water, and dry with a clean cloth or filter paper. 3. The Mercurous Sulphate.
Page 38 - CELL. Definition of the Cell. The cell consists of zinc or an amalgam of zinc with mercury and of mercury in a neutral saturated solution of zinc sulphate and mercurous sulphate in water, prepared with mercurous sulphate in excess. Preparation of the Materials. 1. The Mercury. — To secure purity it should be first treated with acid in the usual manner, and subsequently distilled in vacuo. 2. The Zinc. — Take a portion of a rod of pure redistilled zinc, solder to one end a piece...
Page 39 - Mix the washed mercurous sulphate with the zinc sulphate solution, adding sufficient crystals of zinc sulphate from the stock bottle to ensure saturation, and a small quantity of pure mercury. Shake these up well together to form a paste of the consistence of cream. Heat the paste, but not above a temperature of 30° C.
Page 40 - ... rod can pass tightly ; at the other side bore another hole for the glass tube which covers the platinum wire ; at the edge of the cork cut a nick through which the air can pass when the cork is pushed into the tube. Wash the cork thoroughly with warm water, and leave it to soak in water for some hours before use. Pass the zinc rod about 1 centimetre through the cork.
Page 39 - ... any free acid. The crystals should be dissolved with the aid of gentle heat, but the temperature to which the solution is raised should not exceed 30° C.