A Handbook of Medical Electricity |
From inside the book
Results 1-5 of 10
Page xi
... ( closed ) 40. Uterine Rheophore ( closed ) 39. The same ( open ) 41. The same ( open ) 47 51 54 55 56 58 68 68 68 69 69 70 71 87 88 88 89 89 90 90 42. Laryngeal Rheophore 43. Aural Rheophore 44. Case of Atrophic.
... ( closed ) 40. Uterine Rheophore ( closed ) 39. The same ( open ) 41. The same ( open ) 47 51 54 55 56 58 68 68 68 69 69 70 71 87 88 88 89 89 90 90 42. Laryngeal Rheophore 43. Aural Rheophore 44. Case of Atrophic.
Page 29
... closed , and the battery is out of use , the cells and the contained FIG . 5 . WEISS & SON LONDON 20 exciting fluid are depressed beneath the elements , and the latter are no longer immersed . When the lid of the battery is raised to ...
... closed , and the battery is out of use , the cells and the contained FIG . 5 . WEISS & SON LONDON 20 exciting fluid are depressed beneath the elements , and the latter are no longer immersed . When the lid of the battery is raised to ...
Page 39
... closed , the iron comes in contact with a small plate of platinum fixed in the front of the apparatus on a level with the knob , L. 2. In the further compart- ment of the upper drawer , the zinc ( z , fig . 12 ) , is also prolonged by a ...
... closed , the iron comes in contact with a small plate of platinum fixed in the front of the apparatus on a level with the knob , L. 2. In the further compart- ment of the upper drawer , the zinc ( z , fig . 12 ) , is also prolonged by a ...
Page 46
... ( closed ) . Soft Iron . battery in the lower compartment , A , and the electrodes and their conductors are in the upper compartment B. The induction apparatus is com- posed of the two superposed coils , the wires of which are of ...
... ( closed ) . Soft Iron . battery in the lower compartment , A , and the electrodes and their conductors are in the upper compartment B. The induction apparatus is com- posed of the two superposed coils , the wires of which are of ...
Page 47
... closed as in fig . door , G , of this com- 17 , the small platinized plate L ( fig . 22 ) which communicates with the carbon contained in the caoutchouc cell , comes in contact with the spring , H , which rests against. ELECTRO - MEDICAL ...
... closed as in fig . door , G , of this com- 17 , the small platinized plate L ( fig . 22 ) which communicates with the carbon contained in the caoutchouc cell , comes in contact with the spring , H , which rests against. ELECTRO - MEDICAL ...
Other editions - View all
Common terms and phrases
acid action affected apparatus application arrangement atrophy battery body branch brought caused cells charge coil commutator complete condition conductor connected contained continuous contraction copper cure deltoid diagnosis direct disease Duchenne Duchenne's Edition electricity electrodes elements Enlarged especially excitation experience extremity faradization five fixed followed four give glass graduator hand Hospital Illustrations importance improvement increased induction instrument insulated intermissions interrupted voltaic current iron irritability knob less localized London lower Medical Medicine ment method minutes months movement muscles muscular negative nerve Octavo operator pain paralysis paralyzed passes Pathology patient Physician placed plate pole positive practice Price primary produced Professor proved reaction removed result Revised rheophore rule screw Second Edition shown side skin soft sponge spring sufficiently surface therapeutic Third tion treated treatment turned wasted wire zinc
Popular passages
Page ii - A Treatise on Medical Electricity, Theoretical and Practical ; and its Use in the Treatment of Paralysis, Neuralgia, and other Diseases.