A Handbook of Medical Electricity |
From inside the book
Results 1-5 of 12
Page 31
... desired number of cells can be brought into operation ; and on its upper surface is an ingeniously devised commutator , by turning which to the right or left , the current ELECTRO - MEDICAL INSTRUMENTS . 31 Stöhrer's Battery.
... desired number of cells can be brought into operation ; and on its upper surface is an ingeniously devised commutator , by turning which to the right or left , the current ELECTRO - MEDICAL INSTRUMENTS . 31 Stöhrer's Battery.
Page 42
... desired to obtain rapid intermissions of the trembler ( A , fig . 11 ) , turn from right to left the knob c , which fixes the movable plate , and then turn from left to right the buttons E , G , L , N , so as to bring them into contact ...
... desired to obtain rapid intermissions of the trembler ( A , fig . 11 ) , turn from right to left the knob c , which fixes the movable plate , and then turn from left to right the buttons E , G , L , N , so as to bring them into contact ...
Page 43
Herbert Tibbits. fectly easy to obtain intermissions separated by any desired interval . When the graduator , B , is entirely contained within the instrument , the currents are at the minimum of intensity ; and in order to increase them ...
Herbert Tibbits. fectly easy to obtain intermissions separated by any desired interval . When the graduator , B , is entirely contained within the instrument , the currents are at the minimum of intensity ; and in order to increase them ...
Page 48
... desired , the button , 1 , must be turned from right to left until the bar , E , pushed forward by a platinized eccentric fixed to the button , is sufficiently near to the temporary magnet , J , which is in contact with the soft iron in ...
... desired , the button , 1 , must be turned from right to left until the bar , E , pushed forward by a platinized eccentric fixed to the button , is sufficiently near to the temporary magnet , J , which is in contact with the soft iron in ...
Page 53
... desired , the same indicator , D , must be turned in the op- posite direction , and stopped when its needle points to the number of intermissions which it is desired to obtain for each revolution of the large wheel . The handle , turned ...
... desired , the same indicator , D , must be turned in the op- posite direction , and stopped when its needle points to the number of intermissions which it is desired to obtain for each revolution of the large wheel . The handle , turned ...
Other editions - View all
Common terms and phrases
acid action affected apparatus application arrangement atrophy battery body branch brought caused cells charge coil commutator complete condition conductor connected contained continuous contraction copper cure deltoid diagnosis direct disease Duchenne Duchenne's Edition electricity electrodes elements Enlarged especially excitation experience extremity faradization five fixed followed four give glass graduator hand Hospital Illustrations importance improvement increased induction instrument insulated intermissions interrupted voltaic current iron irritability knob less localized London lower Medical Medicine ment method minutes months movement muscles muscular negative nerve Octavo operator pain paralysis paralyzed passes Pathology patient Physician placed plate pole positive practice Price primary produced Professor proved reaction removed result Revised rheophore rule screw Second Edition shown side skin soft sponge spring sufficiently surface therapeutic Third tion treated treatment turned wasted wire zinc