A Handbook of Medical Electricity |
From inside the book
Results 1-5 of 15
Page 22
Herbert Tibbits. about two feet in diameter . The machine should be fixed upon a firm stand or table , that it may be quite steady during rotation . The one that I habi- tually use is firmly screwed to a heavy painted deal table . It was ...
Herbert Tibbits. about two feet in diameter . The machine should be fixed upon a firm stand or table , that it may be quite steady during rotation . The one that I habi- tually use is firmly screwed to a heavy painted deal table . It was ...
Page 31
... fixed in either position . By this arrangement the acid can be brought into contact with the zinc and carbon , or by shutting down the cells be excluded from them altogether . In the latter case the acid will only fill the lower third ...
... fixed in either position . By this arrangement the acid can be brought into contact with the zinc and carbon , or by shutting down the cells be excluded from them altogether . In the latter case the acid will only fill the lower third ...
Page 38
... fixed to a cell of hard caoutchouc , and of a FIG . 12 . FIG . 13 . Z zinc plate , z z ' , of the same surface as the carbon and separated from it by a cloth diaphragm . The platinum wires which form the carbon contacts are arranged as ...
... fixed to a cell of hard caoutchouc , and of a FIG . 12 . FIG . 13 . Z zinc plate , z z ' , of the same surface as the carbon and separated from it by a cloth diaphragm . The platinum wires which form the carbon contacts are arranged as ...
Page 39
... fixed in the front of the apparatus on a level with the knob , L. 2. In the further compart- ment of the upper drawer , the zinc ( z , fig . 12 ) , is also prolonged by a strip of iron , b . This strip is also bent upwards at a right ...
... fixed in the front of the apparatus on a level with the knob , L. 2. In the further compart- ment of the upper drawer , the zinc ( z , fig . 12 ) , is also prolonged by a strip of iron , b . This strip is also bent upwards at a right ...
Page 42
... fixed to one of the knobs , I , of the pedal rheotome , Y , and the other conductor from the knob , ' of the rheotome , is attached to the button , L ' . It is then only necessary to govern with the foot the spring contact , 2 , of the ...
... fixed to one of the knobs , I , of the pedal rheotome , Y , and the other conductor from the knob , ' of the rheotome , is attached to the button , L ' . It is then only necessary to govern with the foot the spring contact , 2 , of the ...
Other editions - View all
Common terms and phrases
acid action affected apparatus application arrangement atrophy battery body branch brought caused cells charge coil commutator complete condition conductor connected contained continuous contraction copper cure deltoid diagnosis direct disease Duchenne Duchenne's Edition electricity electrodes elements Enlarged especially excitation experience extremity faradization five fixed followed four give glass graduator hand Hospital Illustrations importance improvement increased induction instrument insulated intermissions interrupted voltaic current iron irritability knob less localized London lower Medical Medicine ment method minutes months movement muscles muscular negative nerve Octavo operator pain paralysis paralyzed passes Pathology patient Physician placed plate pole positive practice Price primary produced Professor proved reaction removed result Revised rheophore rule screw Second Edition shown side skin soft sponge spring sufficiently surface therapeutic Third tion treated treatment turned wasted wire zinc