A Handbook of Medical Electricity |
From inside the book
Results 1-5 of 20
Page 22
... months . The cushions should be screwed sufficiently tight to slightly " grip " the plate , and if it is found that notwithstanding having well warmed the flannel and rubbed all the glass of the apparatus , and especially the legs of ...
... months . The cushions should be screwed sufficiently tight to slightly " grip " the plate , and if it is found that notwithstanding having well warmed the flannel and rubbed all the glass of the apparatus , and especially the legs of ...
Page 25
... months , and new zinc plates are needed about every three years . This battery was designed by Mr. Becker , of the firm of Messrs . Elliott Brothers , 449 Strand , and it is supplied by them . Mr. Becker has added to it , as a means of ...
... months , and new zinc plates are needed about every three years . This battery was designed by Mr. Becker , of the firm of Messrs . Elliott Brothers , 449 Strand , and it is supplied by them . Mr. Becker has added to it , as a means of ...
Page 30
... months , by pouring into each cell a measured portion of diluted sulphuric acid ( one part of strong acid to twenty - nine of water ) . A measure holding the requisite amount of acid is supplied with the instrument . To charge it the ...
... months , by pouring into each cell a measured portion of diluted sulphuric acid ( one part of strong acid to twenty - nine of water ) . A measure holding the requisite amount of acid is supplied with the instrument . To charge it the ...
Page 32
... months , or when- ever during use effervescence of the acid is perceived . To re - amalgamate the zincs allow each plate to. Stöhrer's Battery for Hospital use . water ) for which purpose a common tumbler answers well. 32 MEDICAL ...
... months , or when- ever during use effervescence of the acid is perceived . To re - amalgamate the zincs allow each plate to. Stöhrer's Battery for Hospital use . water ) for which purpose a common tumbler answers well. 32 MEDICAL ...
Page 45
... that when after working some hours a day for many months , it becomes oxydized , it may be shifted a little to the left or right , and a new place brought into use . Clean also the point of the screw ELECTRO - MEDICAL INSTRUMENTS . 45.
... that when after working some hours a day for many months , it becomes oxydized , it may be shifted a little to the left or right , and a new place brought into use . Clean also the point of the screw ELECTRO - MEDICAL INSTRUMENTS . 45.
Other editions - View all
Common terms and phrases
acid action affected muscles apparatus application atrophy battery bladder brachial plexus brain caused cells commutator complete conductor contraction copper cord cure cutaneous faradization deformity deltoid diagnosis disease Duchenne Duchenne's elec electricity electrode excitation extensor facial faradization farado-contractility fibres fingers flexor forearm hemiplegia hypothenar eminences Illustrations improvement increased induction instrument Infantile Paralysis insulated inter intermissions interrupted voltaic current irritability knob lead palsy lesion levator scapulæ Leyden jar localized Medical Medicine ment minutes months movement muscles muscular tissue negative pole neuralgia neurolemma nutrition Octavo pain palmaris longus paralyzed muscles paraplegia Pathology patient pedal rheotome pharynx phrenic phrenic nerves placed plate practice Price primary coil produced Radcliffe radial nerve result rheophore rheumatic scapula screw Second Edition secondary coil sensation sensibility shoulder shown in fig side skin soft iron spasm splenius sponge sternomastoid Stöhrer's induction surface Surgical tendons therapeutic tion trembler tricity Volta-faradic voluntary power wasted muscles wire zinc