Page 40
... arrangement which leaves the hands of the operator free , either to hold the con- ductors or to gradulate the currents . Duchenne's large Uncovered Apparatus ( fig . 14 ) differs from that just described in the following respects - 1 ...
... arrangement which leaves the hands of the operator free , either to hold the con- ductors or to gradulate the currents . Duchenne's large Uncovered Apparatus ( fig . 14 ) differs from that just described in the following respects - 1 ...
Page 42
... arrangement is made as before , except that the button , c , is turned from left to right so as to render the plate , A , of the trembler im- movable , and the button , L , from left to right so as to separate it from its platinum ...
... arrangement is made as before , except that the button , c , is turned from left to right so as to render the plate , A , of the trembler im- movable , and the button , L , from left to right so as to separate it from its platinum ...
Page 54
... arranged in the completed apparatus , that it can be moved vertically up and down , and can be fixed at any point . By this ar- rangement the acid can be brought into contact with Stöhrer's Battery . the whole , or with part of the zinc ...
... arranged in the completed apparatus , that it can be moved vertically up and down , and can be fixed at any point . By this ar- rangement the acid can be brought into contact with Stöhrer's Battery . the whole , or with part of the zinc ...
Page 56
... arranged either as two pairs , or as a single pair of elements . Both possess a primary and a secondary coil , the FIG . 26 . Stöhrer's larger Induction Instrument . currents of each of which can be made use of separately ; and in both ...
... arranged either as two pairs , or as a single pair of elements . Both possess a primary and a secondary coil , the FIG . 26 . Stöhrer's larger Induction Instrument . currents of each of which can be made use of separately ; and in both ...
Page 57
... arrangement of the coils . The primary coil is fixed upon a pedestal ; the secondary is movable , and is brought into and placed out of action by being lifted over or thrust away from the primary . The degree of action in the secondary ...
... arrangement of the coils . The primary coil is fixed upon a pedestal ; the secondary is movable , and is brought into and placed out of action by being lifted over or thrust away from the primary . The degree of action in the secondary ...
Other editions - View all
Common terms and phrases
acid action affected muscles apparatus application atrophy battery bladder brachial plexus brain caused cells commutator complete conductor contraction copper cord cure cutaneous faradization deformity deltoid diagnosis disease Duchenne Duchenne's elec electricity electrode excitation extensor facial faradization farado-contractility fibres fingers flexor forearm hemiplegia hypothenar eminences Illustrations improvement increased induction instrument Infantile Paralysis insulated inter intermissions interrupted voltaic current irritability knob lead palsy lesion levator scapulæ Leyden jar localized Medical Medicine ment minutes months movement muscles muscular tissue negative pole neuralgia neurolemma nutrition Octavo pain palmaris longus paralyzed muscles paraplegia Pathology patient pedal rheotome pharynx phrenic phrenic nerves placed plate practice Price primary coil produced Radcliffe radial nerve result rheophore rheumatic scapula screw Second Edition secondary coil sensation sensibility shoulder shown in fig side skin soft iron spasm splenius sponge sternomastoid Stöhrer's induction surface Surgical tendons therapeutic tion trembler tricity Volta-faradic voluntary power wasted muscles wire zinc