A Handbook of Medical Electricity |
From inside the book
Results 6-10 of 15
Page 48
... intermissions should be made slowly , the knob L , ( fig . 20 ) , must be turned till the line traced upon it is directed transversely . If rapid intermissions are desired , the button , I , must be turned from right to left until the ...
... intermissions should be made slowly , the knob L , ( fig . 20 ) , must be turned till the line traced upon it is directed transversely . If rapid intermissions are desired , the button , I , must be turned from right to left until the ...
Page 49
... a magnetic tensor ; of two coils of copper wire of unequal length and thickness ; of a rheotome ; of a regulator of the intermissions ; of a 4 graduator of the currents ; and of a commutator of ELECTRO - MEDICAL INSTRUMENTS . 49.
... a magnetic tensor ; of two coils of copper wire of unequal length and thickness ; of a rheotome ; of a regulator of the intermissions ; of a 4 graduator of the currents ; and of a commutator of ELECTRO - MEDICAL INSTRUMENTS . 49.
Page 50
... intermissions of the magnetic current , is traversed in its centre by a horizontal axis termi- nated at its ... intermissions of the current of induction . As it is possible to make the larger wheel revolve twice in a second , we may ...
... intermissions of the magnetic current , is traversed in its centre by a horizontal axis termi- nated at its ... intermissions of the current of induction . As it is possible to make the larger wheel revolve twice in a second , we may ...
Page 51
... The end of the one is soldered to the be- ginning of the other , while the other ends are brought that of the thick wire to the springs , s and s ' , which produce the intermissions on the. ELECTRO - MEDICAL INSTRUMENTS . 51.
... The end of the one is soldered to the be- ginning of the other , while the other ends are brought that of the thick wire to the springs , s and s ' , which produce the intermissions on the. ELECTRO - MEDICAL INSTRUMENTS . 51.
Page 52
Herbert Tibbits. and s ' , which produce the intermissions on the reel , B ; and that of the fine wire to the right side , u , of the commutator of the coils , T , which conducts the current of the primary coil to the knobs , P and P ...
Herbert Tibbits. and s ' , which produce the intermissions on the reel , B ; and that of the fine wire to the right side , u , of the commutator of the coils , T , which conducts the current of the primary coil to the knobs , P and P ...
Other editions - View all
Common terms and phrases
acid action affected muscles apparatus application atrophy battery bladder brachial plexus brain caused cells commutator complete conductor contraction copper cord cure cutaneous faradization deformity deltoid diagnosis disease Duchenne Duchenne's elec electricity electrode excitation extensor facial faradization farado-contractility fibres fingers flexor forearm hemiplegia hypothenar eminences Illustrations improvement increased induction instrument Infantile Paralysis insulated inter intermissions interrupted voltaic current irritability knob lead palsy lesion levator scapulæ Leyden jar localized Medical Medicine ment minutes months movement muscles muscular tissue negative pole neuralgia neurolemma nutrition Octavo pain palmaris longus paralyzed muscles paraplegia Pathology patient pedal rheotome pharynx phrenic phrenic nerves placed plate practice Price primary coil produced Radcliffe radial nerve result rheophore rheumatic scapula screw Second Edition secondary coil sensation sensibility shoulder shown in fig side skin soft iron spasm splenius sponge sternomastoid Stöhrer's induction surface Surgical tendons therapeutic tion trembler tricity Volta-faradic voluntary power wasted muscles wire zinc